ACT系列嵌入式轉速表 Panel Type Tachometer

ACT系列嵌入式轉速表

光電轉速表為接觸和非接觸兩型。具有精度高、范圍大、測量距離遠的有點。特別是激光型,其測量距離可達7m(米)遠。ACT系列轉速表為嵌入式轉速表,方便和大型機械設備配套使用。

ACT-3XThumb

Panel Tachometers: ACT Series

The ACT-1B Panel Tachometer can be factory configured to meet your specifications or user configured on site with the optional USB Programming Cable and Software

The ACT-3X Panel Tachometer is a powerful NIST calibrated fully programmable tachometer and totalizer. It accepts inputs from all Monarch speed sensors or from any standard TTL generating device. The unit operates from 120/240Vac input power or from 12 or 24Vdc input power (optional). Programming is easily performed through the 5 front panel push buttons or using the optional PM Remote Software. Set up for single channel monitoring or use the auxiliary second channel input. Programmable scale factor with menu selection for multiple pulses per revolution, linear rates, totalization, single event trip speeds and rate of change in rpm. A TTL pulse repeater output is standard.

FEATURES

All models – Universal Input, non-contact operation from optical, infrared, laser, proximity, and magnetic sensors or direct TTL and 200mV to 50 Vac signals

ACT-1B Panel Tachometer
· Economically priced
· 1/8 DIN sized
· 5 Digit LED display
· 5 to 99,999 RPM range
· Universal sensor inputs
· Compatible with most speed sensors
· User configurable*
· View real-time data on PC*
· Store data in Excel File in real-time*
· Universal A/C power 100 to 240 Vac, 50/60Hz or optional DC input power
· Optional 4-20mA or 0-5Vdc scalable output
*Requires optional USB programming cable and PM Remote Software

ACT-3X Panel Tachometer
· 1/8 DIN sized
· 5 Digit LED display
· 5 to 999,990 RPM range
· Universal sensor inputs
· N.I.S.T. Traceable Certificate of Calibration included
· User configurable with front panel push buttons or Optional PM Remote Software
· View real-time data on PC*
· Store data in Excel File in real-time*
· Universal A/C power 100 to 240 Vac, 50/60Hz or optional 12 or 24Vdc power
· Standard pulse repeater output
· Single event capture from start ans stop pulses, in units such as MPH, CM/sec, etc. Using
two sensors – for linear rate of travel on second input channel
· Optional 4-20mA or 0-5Vdc scalable output
· Optional Ethernet or USB communications
· Optional alarm relay outputs
*Requires optional USB programming cable and PM Remote Software

ACT-1BFrontRear200

ACT3XFrontRear200

 

ACT-1B Specifications

Speed Range: 5 to 99,999 RPM
Accuracy: ±1 RPM or 0.005% of reading
Resolution: 1 RPM
Display: 5 digit, 0.56” (14 mm) high red LED.

Display Update:
Twice per second above 120 RPM. Programmable with PM Remote Software and USB programming cable.

Dimensions:
1/8 DIN by 4.5” (114 mm) deep. Panel cutout: 3.58” x 1.74” (91 x 44mm)

Input Power:
Standard: 100 – 240 Vac ±10%, 50/60 Hz Optional: 12 or 24 Vdc ±10%, Isolated, 6.0 Watts.

Inputs:
Universal input for optical, proximity, two wire or three wire magnetic, infrared or laser sensors. TTL input or 1.5 Vac to 50 Vac
input. Standard input is 1 pulse per revolution.
Sensor Excitation:
5Vdc or optional 12Vdc or 24Vdc to sensor.

Recommended Sensors:
Optical – Monarch ROS-W, ROS-P-25, ROS-HT-W-25, ROSM-5W
Proximity – Monarch P5-11
Magnetic – Monarch M-190W or MT-190W
Infrared – Monarch IRS-W
Laser – Monarch ROLS-W, SLS-115/230
Inductive – Gas Engine GE-200

Analog Output:
(Optional)
VOLTAGE (AO): 0 to 5 Vdc out, 5 mA 16 bit resolution. Full scale RPM settings as specified when ordered or programmable using PM Remote Software and USB programming cable. or CURRENT (IO): 4 to 20 mA out, 16 bit resolution 12Vdc compliance voltage. Full scale RPM settings as specified when ordered or programmable using PM Remote Software and USB programming cable.
Pulse Output: (Optional) 0 to 5 V TTL pulse, non-inverting, one pulse out for each pulse in. Positive or negative out. Programmable using PM
Remote Software and USB programming cable.
Remote Programming:
Unit can be remotely programmed using optional communications interface cable and PM Remote Software.
Environmental:
Indoor use only, Installation category II per IEC 664 Temperature: -10°C to 50°C operating per IEC 61010-1 Humidity: Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C.
Electrical Safety:
Meets EN61010-1:2001, EC low voltage directive 72/23/EEC and 89/336/EEC

 

ACT-3X Specifications

Speed Range:
5 to 999,990 RPM (single pulse per revolution), 0.5 to 999,990 RPM (10 pulses per revolution). Speeds below 5 RPM are possible with multiple pulses per revolution
Input Frequency Range:
0.083 Hz to 250 kHz
Totalizer/Counter:
Display Range: 0.001 to 99,999 (Only top 5 digits are shown for 100,000-999,990) Max # of counts = 16,777,216 even with 0.001 scale
Input Configuration:
Universal Inputs: 1 to 9,999 pulses per revolution, front panel push button programmable TTL input and 1.1V to 50vac signals, Opt: -1 to – 50Vdc
Accuracy:
±0.001% of reading or ±1 displayed resolution (Standard Gate), ±0.01% of reading or ±1 displayed resolution (Fast Gate).
Resolution:
Up to 0.001 RPM, 10 RPM (100,000 to 999,990 RPM).
Display:
5 digit, 0.56” (14 mm) high red LED.
Display Update:
Menu Selectable between: 0.5 second above 120 RPM, 1 second above 60 RPM and 1.5 seconds above 40 RPM.
Max Measurement Rate:
Up to 100 times per second (Standard Gate) or up to 1000 (Fast Gate) dependent on input frequency. Input must be
> measurement rate.
Scaling:
Programmable scaling: 0.0001 to 9999.9 (front panel push button programmable).
Decimal Point:
User Selectable (0-3) decimal places max (front panel push button programmable).
Memory:
Maximum, minimum and last reading recall from front panel push buttons.
Dimensions:
1/8 DIN by 4.5” (114 mm) deep. Panel cutout: 3.58” x 1.74” (91 x 44mm)
Input Power:
Standard: 100 – 240 Vac ±10%, 50/60 Hz Optional: 12 or 24 Vdc ±20%, Isolated, 6.0 Watts.
Inputs:
Universal input for optical, proximity, two wire or three wire magnetic, infrared or laser sensors. TTL input or 1.5 Vac to 50 Vac input. Standard input is 1 pulse per revolution.
Sensor Excitation:
5Vdc or optional 12Vdc or 24Vdc to sensor.
Recommended Sensors:
Optical – Monarch ROS-W, ROS-P-25, ROS-HT-W-25, ROSM-5W
Proximity – Monarch P5-11
Magnetic – Monarch M-190W or MT-190W
Infrared – Monarch IRS-W
Laser – Monarch ROLS-W, SLS-115/230
Inductive – Gas Engine GE-200
Pulse Repeater Output:
Standard, 0 to 5 V TTL compatible. One pulse out for each pulse in. Menu selectable polarity.
Communications:
Bi-directional RS232C, USB or Ethernet interface.
Analog Output:
Voltage (AO): 0 to 5 Vdc, 5mA max load (isoloated or non-isolated) or Current (IO): 4 to 20mA, 500Ω max load. (isolated or non-isolated), 1 to 5Vdc possible using 250Ω resistor) 16 bit resolution. Front panel push button programmable for full scale and offset RPM ranges.
Alarm Capability:
Two alarm set points: High or Low alarm limits, Latching or Non-Latching, Front panel push button programmable Hysteresis, dead band and low limit lockout are programmable, Relays can be set as failsafe. Alarms can be reset Manually or Automatically. Remote reset via auxiliary input.
Alarm Outputs:
Two Form C relay contacts, rated 1A at 115Vac or 230Vac
Remote Programming:
Unit can be remotely programmed using optional communications interface and PM Remote Software.
Environmental:
Indoor use only, Installation category II per IEC 664 Temperature: -10°C to 50°C operating per IEC 61010-1 Humidity: Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C.
Electrical Safety:
Meets EN61010-1:2001, EC low voltage directive 72/23/EEC and 89/336/EEC


 

 
聯絡我們 Contact us:

香港 Hong Kong: Tel. 852 2691 3821 Fax. 852 2900 2980
中國 China: Tel. 86 150 17992655
電郵 Email: labsupplyhk@gmail.com
網址 Web: http://www.etc.hk

留言表格 Inquiry Form: